BIT SWITCHES
System Switch 0F
No
FUNCTION
0
Country code for functional settings
to
(Hex)
7
00: France
10: Not used
01: Germany
11: USA
02: UK
12: Asia
03: Italy
13: Japan
04: Austria
14: Hong Kong
05: Belgium
15: South Africa
06: Denmark
16: Australia
07: Finland
17: New Zealand
08: Ireland
18: Singapore
09: Norway
19: Malaysia
0A: Sweden
1A: China
0B: Switz.
1B: Taiwan
0C: Portugal
20: Turkey
0D: Holland
21: Greece
0E: Spain
0F: Israel
System Switch 10
No
FUNCTION
0
Threshold memory level for
to
parallel memory transmission
7
System Switch 11
No
FUNCTION
0 TTI printing position
0: Superimposed on the
page data
1: Printed before the data
leading edge
1 TSI (G3) or CIL (G4) printing
position
0: Printed before the data
leading edge
1: Superimposed on the
page data
2
Not used
to
6
7 Use of parallel memory
transmission with G4
transmission
0: Disabled
1: Enabled
SM
This country code determines the factory
settings of bit switches and RAM addresses.
However, it has no effect on the NCU
parameter settings and communication
parameter RAM addresses.
Cross reference
NCU country code: Function 06, parameter
C.C.
Threshold = N x 64 kbytes + 256 kbytes
N can be between 00 - FF(H)
Default setting: 04(H) = 512 kbytes
Change this bit to 1 if the TTI overprints information that
the customer considers to be important (G3
transmissions).
Change this bit to 1 if the TSI (G3) or CIL (G4)
overprints information that the customer considers to be
important.
Do not change the factory settings.
This determines whether parallel transmission can be
used with a G4 transmission or not.
Note that this bit is only effective if Parallel Memory
transmission is enabled (User Parameter 07 - bit 2).
Refer to Parallel Memory Transmission in section 2.
4-26
COMMENTS