System Switch 00
No
FUNCTION
3 Line quality data output
method
0: Measure of error rate
(during image data
transmission only)
1: Rx level
4 Line error marks on received
pages
0: Disabled
1: Enabled
5 G3/G4 Communication
parameter display
0: Disabled
1: Enabled
6 Protocol dump list output
after each communication
0: Off 1: On
7 Amount of protocol dump
data in one protocol dump list
printout operation
0: Up to the limit of the
memory area for protocol
dumping
1: Last communication only
(A639)
COMMENTS
This bit determines the data type to be printed on the
TCR (Journal) when technical data printout is enabled
by bit 2 above.
If this bit is 1, a mark will be printed on the left edge of
the page at any place where a line error occured in the
data. Such errors are caused by a noisy line, for
example.
This is a fault-finding aid. The LCD shows the key
parameters (see the next 2 pages). This is normally
disabled because it cancels the CSI display for the user.
Be sure to reset this bit to 0 after testing.
This is only used for communication troubleshooting. It
shows the content of the transmitted facsimile protocol
signals. Always reset this bit to 0 after finishing testing.
Change this bit to 1 if you want to have a protocol dump
list of the last communication only.