Communication Switch 0D
No
FUNCTION
0
The available memory
to
threshold, below which
7
ringing detection (and
therefore reception into
memory) is disabled
Communication Switch 0E
No
FUNCTION
0
Minimum interval between
to
automatic dialing attempts
7
Communication Switch 0F
No
FUNCTION
0
Minimum number of times
to
that a destination will dialed
7
when TRD is being used
Communication Switch 10
No
FUNCTION
0
Memory transmission:
to
Maximum number of dialing
7
attempts to the same
destination
Communication Switch 11 - Not used (do not change the settings.)
Communication Switch 12
No
FUNCTION
0
Memory transmission:
to
Interval between dialing
7
attempts to the same
destination
Communication Switch 13 - Not used (do not change the settings.)
(A639)
COMMENTS
00 to FF (Hex), unit = 2 kbytes
(e.g., 0C(H) = 24 kbytes)
One page is about 24 kbytes.
The machine refers to this setting before each fax
reception. If the amount of remaining memory is below
this threshold, the machine can not receive any fax
messages.
If this setting is kept at 0, the machine will detect ringing
signals and go into receive mode even if there is no
memory available. This will result in communication
failure.
COMMENTS
06 to FF (Hex), unit = 2 s
(e.g., 06(H) = 12 s)
This value is the minimum time that the machine waits
before it dials the next destination.
COMMENTS
01 - FF (Hex) times
COMMENTS
01 - FF (Hex) times
COMMENTS
01 - FF (Hex) minutes
4-45