2. SC CODE DESCRIPTIONS
SC120: Scanner home position error 1
-Definition- [B]
The scanner home position sensor does not detect the off condition
during initialization or copying.
- Possible causes -
Scanner home position sensor defective
Scanner drive motor defective
IOSCC board defective
Scanner home position sensor harness defective
SC121: Scanner home position error 2
-Definition- [B]
The scanner home position sensor does not detect the on condition
during initialization or copying.
- Possible causes -
Scanner home position sensor defective
Scanner drive motor defective
IOCSS board defective
Scanner home position sensor harness defective
SC122: Scanner home position error 3
-Definition- [B]
The scanner home position sensor detects the on condition when the
scanner is returning to the home position.
- Possible causes -
Scanner home position sensor defective
Scanner drive motor defective
IOCSS board defective
Scanner home position sensor harness defective