IC CARDS
6. Function Upgrade Card only:
The following message appears on the display:
Caution! Installing a function upgrade card causes data loss. Turn off the
ac switch and remove it to avoid data loss.
To continue, press 'yes'.
Press 'Yes'.
7. Print the system parameter list. Check the following:
SAF memory card
"2M" or "4M" is listed as an option on the system parameter list, and that
the remaining memory indicator shows 100%.
Page Memory Card (High Resolution Card)
"PM" is listed as an option on the system parameter list.
Function Upgrade Card
"Function Upgrade" is listed as an option on the system parameter list.
8. Connect the telephone cable to the NCU.
5.2 ITEMS INITIALIZED WHEN FUNCTION UPGRADE CARD IS
INSTALLED OR REMOVED
Items initialized, at the function upgrade card installation, when the machine
displays the following message:
Caution! Installing a function upgrade card causes data loss. Turn off the
ac switch and remove it to avoid data loss.
To continue, press 'yes'.
All SAF files and Polling Rx files
All Auto Documents
All Specified Addresses
All Communication Records for TCR/Journal
SM
3-14
(A639)