BIT SWITCHES
G3 Switch 09
FUNCTION
4
Not used
to
7
G3 Switch 0A
FUNCTION
0
Maximum allowable carrier
drop during image data
1
reception
Bit 1
Bit 0
Value (ms)
0
0
200
0
1
400
1
0
800
1
1
Not used
2 Not used
3
4 Maximum allowable frame
interval during image data
reception.
0: 5 s
1: 13 s
5 Not used
6 Reconstruction time for the
first line in receive mode
0: 6 s
1: 12 s
7 Not used
SM
Do not change the settings.
These bits set the acceptable modem carrier drop time.
Try using a longer setting if error code 0-22 is frequent.
Do not change the settings.
This bit set the maximum intervals between each EOL
signal (end-of-line) or intervals between each ECM
frame from the other end.
Try using a longer setting if error code 0-21 is frequent.
Do not change the settings.
When the sending terminal is controlled by a computer,
there may be a delay in receiving page data after the
local machine accepts set-up data and sends CFR. This
is outside the T.30 recommendation. But, if this delay
occurs, set this bit to 1 to give the sending machine
more time to send data.
Refer to error code 0-20.
ITU-T T.30 recommendation: The first line should come
within 5 seconds of CFR.
Do not change the settings.
4-52