+5VE is the 5 volt supply for energy saver mode. It saves energy by
supplying +5V power only for the components needed in energy saver mode.
Note that turning the main switch off is the same as entering auto shut off
mode.
Returning to standby mode
- From energy saver level 1 or 2 -
If one of the following is performed, the machine returns to standby mode:
Pressing the Clear Mode/Energy Saver key
Placing an original in the ADF
Lifting the ADF cover
The recovery time from energy saver level 1 is about 3 seconds.
The recovery time from energy saver level 2 is about 10 seconds (115 V
machines) or about 35 seconds (230 V machines).
- From auto shut off mode -
The machine returns to the ready condition when the main switch is turned
on.
The recovery time is less than 30 secondsfor 115V machines, and less than
35 seconds for 230V machines.
Power Consumption
Mode
Main
Switch
Energy Saver
On
Level 1
Energy Saver
Level 2
On
Auto Shut Off
Mode
Off
SM
Energy
Fusing
System
Saver LED
Lamp
+5V
On
165°C
On
140°C
(115V)
On
On
Room T
(230V)
Off
Off
Off
2-65
ENERGY SAVER MODES
Note
The machine returns to standby
mode if the DF is lifted or an
original is placed in the ADF.
The machine returns to standby
mode only if the main switch is
turned on.
(A193)