BIT SWITCHES
System Switch 06 - Not used (Do not change the factory settings.)
System Switch 07 - Not used (Do not change the factory settings.)
System Switch 08 - Not used (Do not change the factory settings.)
System Switch 09
No
FUNCTION
0 Addition of part of the image
data from confidential
transmissions on the
transmission result report
0: Disabled 1: Enabled
1 Inclusion of communications
on the TCR when no image
data was exchanged.
0: Disabled 1: Enabled
2 Automatic error report printout
0: Disabled 1: Enabled
3 Printing of the error code on
the error report
0: No 1: Yes
4 Not used
5 Power failure report
0: Disabled 1: Enabled
6 Not used
7 Priority given to various types
of remote terminal ID when
printing reports
0: RTI > CSI > Dial label >
Tel. number
1: Dial label > Tel. number >
RTI > CSI
SM
If this feature is enabled, the top half of the first page of
confidential messages will be printed on transmission
result reports.
0: Communications which reached phase C (message
tx/rx) of the T.30 protocol are listed on the TCR
(Journal).
1: Communications which reached phase A (call setup)
of T.30 protocol are listed on the TCR (Journal). This
will include telephone calls.
0: Error reports will not be printed.
1: Error reports will be printed automatically after failed
communications.
1: Error codes are printed on the error reports.
Do not change the settings.
1: A power failure report will be automatically printed
after the power is switched on if a fax message
disappeared from the memory when the power was
turned off last.
Do not change the settings.
This bit determines which set of priorities the machine
uses when listing remote terminal names on reports.
In G4 communication, G4_TID (Terminal ID) is used
instead of RTI or CSI.
Dial Label: The name stored, by the user, for the
Quick/Speed Dial number.
4-24
COMMENTS
(A639)