[A]
[B]
[C]
[D]
2. Push the hook [A] of the face-up tray shaft cover [B] and remove it.
3. Remove the face-up tray [C].
4. Remove the caps [D] and the connector cover [E].
5. Peel off the backing of the double sided tapes [F] of the grounding plate
[G].
6. Peel off the protective seals from both side tapes [F] of the grounding
plate [G]. Insert the grounding plate into the center position between the
main unit and the optional paper tray unit.
CAUTION
Do not touch the copper contacts on the grounding plate.
(A666)
[E]
[F]
12-19