Gestetner A193 Service Manual page 172

Table of Contents

Advertisement

Mode No.
Class
Class 3
1 and 2
Side-to-Side
Registration
(4th paper
4
feed: Option
PFU tray 2)
Side-to-Side
Registration
1-002 *
By-pass feed
5
(-T)
Side-to-Side
Registration
(Duplex)
6
Paper Feed
Timing
1
(Paper Feed
1-003 *
Trays)
Paper Feed
2
Timing
By-pass (-T)
Double copy
registration
1-006 *
By-pass Feed
1-007 *
Paper Size
Display
Fusing
Temperature
1
Setting
(Operation)
Fusing
1-105 *
Temperature
Adjustment
2
(Energy Saver
Level 2)
Fusing
1-106
Temperature
Display
Auto Restart
1-901
Interval
SM
Function
Adjusts the printing side-to-side
registration from the 4th paper feed
station using the Trimming Area Pattern
(SP5-902, No.10).
Use the •/∗ key to toggle between + and -.
The specification is 2 ± 1.5 mm.
Adjusts the printing side-to-side
registration from the by-pass feed table
using the Trimming Area Pattern
(SP5-902, No.10).
Use the •/∗ key to toggle between + and -.
The specification is 2 ± 1.5 mm.
Adjusts the printing side-to-side
registration from the duplex tray using the
Trimming Area Pattern (SP5-902, No.10).
Use the •/∗ key to toggle between + and -.
The specification is 2 ± 1.5 mm.
Adjusts the relay clutch timing at
registration. The relay clutch timing
determines the amount of paper buckle at
registration. (A larger setting leads to
more buckling.)
Display Message: Regist. curl adjustment
Adjusts the position of the second copy
from the center line in double copy mode.
Use the •/∗ key to toggle between + and -.
See "Replacement and Adjustment -
Copy Image Adjustments" for details.
Displays the paper width sensor data for
the by-pass feed table.
Adjusts the fusing temperature in the
operation mode.
Adjusts the fusing temperature in the
energy saver level 2 mode.
With a lower value, the machine takes
more time to reach the ready condition.
Displays the fusing temperature.
ö
Press the
key to exit the display.
Do not change the value.
4-7
SERVICE PROGRAM MODE
Settings
+9 ~ -9
0.1 mm/step
+ 0.0 mm
+9 ~ -9
0.1 mm/step
+ 0.0 mm
+9 ~ -9
0.1 mm/step
+ 0.0 mm
0 ~ 10
1 mm/step
7 mm
0 ~ 10
1 mm/step
8 mm
+9 ~ -9
1 mm/step
+ 0 mm
100 ~ 200
1°C/step
180°C
0 ~ 165
1°C/step
140°C (115V
machine)
0°C (230V
machine)
(A193)