ERROR CODES
Code
Meaning
0-07
No post-message
response from the other
end after a page was sent
0-08
The other end sent RTN
or PIN after receiving a
page, because there were
too many errors
0-14
Non-standard post
message response code
received
0-15
The other end does not
have the confidential or
transfer function
0-16
CFR or FTT not detected
after modem training in
confidential or transfer
mode
0-17
Communication was
interrupted by pressing the
Stop key.
Suggested Cause/Action
Check the line connection.
Check the FCU - NCU connectors.
Replace the NCU or FCU.
The other end may have jammed or run out of paper.
The other end user may have disconnected the call.
Check for a bad line.
The other end may be defective; try sending to another
machine.
Check the line connection.
Check the FCU - NCU connectors.
Replace the NCU or FCU.
The other end may have jammed, or run out of paper
or memory space.
Try adjusting the tx level and/or cable equalizer
settings.
The other end may have a defective
modem/NCU/FCU; try sending to another machine.
Check for line problems and noise.
Cross reference
Tx level - NCU Parameter 01 (PSTN)
Cable equalizer - G3 Switch 07 (PSTN)
Dedicated Tx parameters - Section 4
Check the FCU - NCU connectors.
Incompatible or defective remote terminal; try sending
to another machine.
Noisy line: resend.
Try adjusting the tx level and/or cable equalizer
settings.
Replace the NCU or FCU.
Cross reference
See error code 0-08.
The other terminal does not have the confidential rx or
transfer function, or the other terminal's memory is full.
Check the line connection.
Check the FCU - NCU connectors.
Replace the NCU or FCU.
Try adjusting the tx level and/or cable equalizer
settings.
The other end may have disconnected, or it may be
defective; try calling another machine.
If the rx signal level is too low, there may be a line
problem.
Cross reference
See error code 0-08.
If the Stop key was not pressed and this error keeps
occurring, replace the operation panel or OPU.
6-2