Mode No.
Class
Class 3
1 and 2
PCU Alarm
Interval
1
5-912*
PCU Alarm
2
Mode
User Program
(UP) Mode
5-913
Data Reset
Fax
Forwarding
Mode
5-930*
Program
Download
5-932
Image
Rotation Mode
5-940*
Duplex Blank
5-941*
Page
Image
5-942*
Compression
Method
Charge Roller
H.P Detection
5-943*
APS Mode
5-944*
SM
SERVICE PROGRAM MODE TABLE
Function
Inputs the PCU alarm interval.
When the machine reaches the value,
"Change Photoconductor Unit" will be
displayed on the LCD to inform the user.
Selects whether the PCU alarm function
is performed or not.
Resets the UP mode data to the defaults,
except for the user codes, counters for
each user code, and restricted access
features.
Selects whether the fax mode application
key is accepted or not in the SC condition.
When an SC condition occurs while
incoming data has been stored in the SAF
memory, change the value to "1" to
access fax mode. Then forward the
incoming data to another fax machine by
using the fax mode bit switches.
Downloads the system program from a
ROM board to the Flash Memory on the
BICU board. (Copier mode software only)
See "Service Tables - Program
Download" for details.
This SP can be operated when the ROM
board is installed in the machine .
Selects whether the image rotation
function is performed or not.
If there is a problem with the MSU, image
rotation may lead to abnormal copies. If
so, disable image rotation while waiting
for new parts.
Selects whether the blank page is made
on the front side or back side when
duplex copy mode is selected.
Selects the image compression method
for memory mode copying.
Selects whether the charge roller home
position is detected or not.
Do not use in the field, except in the
following case.
If the power goes off during TD sensor
initialization, the charge roller is in contact
with the PCU, so the PCU cannot be
removed. Set SP 5-943 to 1, and the
roller goes back to home position.
Selects whether the APS mode is
selected as power-up default or not.
13-39
Settings
1 ~ 255
1 k / Step
45 k
0: No
1: Yes
0: No
1: Yes
0: No
1: Yes
0: No
1: Yes
0: Yes
1: No
0: Back side
1: Front side
0: MH
1: MR
2: MMR
0: No
1: Yes
0: No
1: Yes