DETAILED DESCRIPTIONS
2.8.4 Jam Detection
1. Face-up Mode
Jam 1: The entrance sensor stays on for 4.2 s.
Jam 2: The exit sensor stays off 3.5 s after the entrance sensor turns on.
Jam 3: The exit sensor stays on for 2.0 s.
2. Face-down Mode
Jam 1: The entrance sensor stays on for 4.2 s.
Jam 2: The inverter sensor stays off 1.5 s after the entrance sensor turns on.
Jam 3: The inverter sensor stays on for 4.2 s.
Jam 4: The exit sensor stays off 0.6 s after the inverter sensor turns off.
Jam 5: The exit sensor stays on for 1.2 s.
3. Staple Mode
Jam 1: The entrance sensor stays on for 2.5 s.
Jam 2: The inverter sensor stays off 1.5 s after the entrance sensor turns on.
Jam 3: The inverter sensor stays on for 0.8 s.
Jam 4: The jogger unit paper sensor stays off 0.5 s after the inverter sensor
turns off.
Jam 5: The exit sensor stays off 1.05 s after the feed-out motor turns on.
Jam 6: The exit sensor stays on for 0.85 s.
Staple Jam: The staple hammer HP switch stays off 0.48 s after the staple
motor turns on.
SM
12-16