DETAILED DESCRIPTIONS
2. DETAILED DESCRIPTIONS
2.1 ORIGINAL SIZE DETECTION
[D]
[E]
[C]
[B]
[A]
The DF has three width sensors (- 1 [A], - 2 [B], and - 3[C]) to detect the
original width and two original length sensors (-1 [D] and -2 [E]) to detect the
original length. The DF will determine the original size through the
combination of those five sensors as shown in the table on the next page.
When using a non-standard size original, the user will need to input the
original length at the operation panel.
(A661)
11-6
SM