REPLACEMENT AND ADJUSTMENT
14.6 FUSING UNIT FAN
[A]
1. Remove the front cover and rear cover.
2. Remove the PCU, transfer roller unit, fusing unit, duplex inverter unit,
duplex unit, paper feed tray, and inner cover.
3. Remove the PSU.
4. Disconnect the fusing unit fan harness [A] and unclamp the harness from
the harness clamps.
5. Cut the clamp [B].
NOTE: Take care not to cut the harnesses.
6. Remove the duplex entrance guide [C].
7. Remove the total counter [D] (1 connector).
8. Remove the fusing unit fan bracket [E] (3 screws).
9. Remove the fusing unit fan [F] (2 screws, 1 connector).
A224
[B]
A224R503.wmf
[D]
13-62
[C]
[E]
[F]
A224R504.wmf