Gestetner A193 Service Manual page 471

Table of Contents

Advertisement

Mode No.
Class
Class 3
1 and 2
Free Run
5-802
Input Check
5-803
Output Check Turns on the electrical components
5-804
Display
Language
1
(115V
machines)
Display
Language
(230V
2
machines -
5-808*
Standard)
Display
Language
(230V
3
machines -
Option)
SC Code
Reset
5-810
Service
Telephone
Number
5-812 *
CSS Function Japanese version only.
5-816*
1
CE Start Call
5-817
CE Finish Call
2
SM
SERVICE PROGRAM MODE TABLE
Function
Performs a free run for both the scanner
and the printer.
To perform the free run, press 1 then
press
twice. Press
Displays the signals received from
sensors and switches.
See the "INPUT CHECK" section for
details.
Press
to exit the program.
individually for test purposes.
See the "OUTPUT CHECK" section for
details.
Selects the display language for 115V
machines.
Selects the standard display language for
230V machines.
Selects the option display language for
230V machines.
Resets Type A service call conditions.
After performing this SP mode, turn the
machine main switch off and on. See
"Troubleshooting - Service Call
Conditions" for how to use this mode.
Use this to input the telephone number of
the service representative (this is
displayed when a service call condition
occurs).
Press the " • /#" key if you need to input a
pause (  ).
Press the
key to delete the
telephone number.
Do not change the value.
Japanese version only.
Do not change the value.
13-37
Settings
0: No
1: Yes
to stop.
0: English
1: French
2: Spanish
0: English
1: German
2: Dutch
3: French
4: Italian
5: Spanish
0: English
1: German
2: Dutch
3: Swedish
4: Norwegian
5: Danish
0: No
1: Yes
A224

Advertisement

Table of Contents
loading

This manual is also suitable for:

A224