1. AUTOMATIC SERVICE CALLS

1.1 SERVICE CALL CONDITIONS
The fax unit makes an automatic service call when an SC code, other than
the following, is informed from the base copier's BiCU.
Note
The service station's fax number has to be programmed in
advance, for the machine to make a service call.
Exceptions
Address (H)
49FB64
1st SC code - High byte (BCD)
49FB65
1st SC code - Low byte (BCD)
49FB66
2nd SC code - High byte (BCD)
49FB67
2nd SC code - Low byte (BCD)
49FB68
3rd SC code - High byte (BCD)
49FB69
3rd SC code - Low byte (BCD)
49FB6A
4th SC code - High byte (BCD)
49FB6B
4th SC code - Low byte (BCD)
49FB6C
5th SC code - High byte (BCD)
49FB6D
5th SC code - Low byte (BCD)
49FB6E
6th SC code - High byte (BCD)
49FB6F
6th SC code - Low byte (BCD)
49FB70
7th SC code - High byte (BCD)
49FB71
7th SC code - Low byte (BCD)
49FB72
8th SC code - High byte (BCD)
49FB73
8th SC code - Low byte (BCD)
49FB74
9th SC code - High byte (BCD)
49FB75
9th SC code - Low byte (BCD)
49FB76
10th SC code - High byte (BCD)
49FB77
10th SC code - Low byte (BCD)
To add additional SC codes, program them in the blank addresses.
The fax unit cannot make an automatic service call when a Fax SC code
condition has occurred. Refer to Troubleshooting for Fax SC code details.
Manual Service Call
If the service station needs a report, the user can make a service call
manually, by setting bit 7 of User Parameter 14 (0E) to '1'.
(A639)
Definition
2-1
AUTOMATIC SERVICE CALLS
Default
SC code
01
192
SBU adjustment error
92
01
193
APS sensor error
93
03
390
TD sensor error 1
90
03
393
TD sensor error 2
93
06
691
BiCU/FCU
91
communication error
09
980
BiCU program load error
80
FF
Not programmed
FF
FF
Not programmed
FF
FF
Not programmed
FF
FF
Not programmed
FF
SM