Rev. 2/28/97
SC692: Communication error between BiCU and printer controller
-Definition- [B]
The BICU board cannot communicate with the printer controller properly.
- Possible causes -
Poor connection of the interface harness which connects the BICU board
and the mother board.
Poor connection between the mother board and the printer controller
BICU board defective
Printer controller defective
Mother board defective
SC900: Total counter error
-Definition- [C]
The total counter is not working properly.
- Possible causes -
Total counter defective
IOCSS board defective
Fuse #5, PSU blown
SC920: MSU connection error
-Definition- [B]
The MSU set signal is not detected
- Possible cause -
Poor connection between the BICU board and the MSU
BICU board defective
MSU defective
SC921: MSU hardware error
-Definition- [B]
The hardware of the MSU is defective
- Possible cause -
MSU defective
BICU defective