BIT SWITCHES
Communication Switch 03
No
FUNCTION
0
Maximum number of page
to
retransmissions in a G3
7
memory transmission
Communication Switch 04 - Not used (do not change the settings)
Communication Switch 05 - Not used (do not change the settings)
Communication Switch 06
No
FUNCTION
0 Dialing requirements:
Germany
0: Disabled 1: Enabled
1 Dialing requirements: Austria
0: Disabled 1: Enabled
2 Dialing requirements: Norway
0: Disabled 1: Enabled
3 Dialing requirements:
Denmark
0: Disabled 1: Enabled
4 Dialing requirements: France
0: Disabled 1: Enabled
5 Dialing requirements:
Switzerland
0: Disabled 1: Enabled
6 Not used
7
Communication Switch 07
No
FUNCTION
0 Fallback from G4 to G3 if the
other terminal is not a G4
terminal
0: Disabled 1: Enabled
1 Not used
2 Use of the date and time
provided from the network for
the CIL
0: Disabled 1: Enabled
3
Not used
to
7
SM
00 - FF (Hex) times.
This setting is not used if ECM is switched on.
Default setting - 03(H)
These switches are automatically set to the settings
required by each country after a country code (System
Switch 0F) is programmed.
Do not change the settings.
Also see System Switch 0A bit 7.
Refer to the ISDN G4 option service manual (G4
Internal Switches 17, 18, 1A, 1B, and 1C) for the CPS
code set (Cause Value set) to determine G4 to G3
fallback.
Do not change the setting.
0: The date and time programmed in the receiving
terminal is used in the CIL.
1: The date and time informed in the document layer
from the remote terminal (through the network) is used
in the CIL.
Do not change the settings.