SC322: Laser synchronization error (A193/A224)
-Definition- [B]
The laser synchronization signal cannot be detected by the main scan
synchroniziation detector board for more than 5 consecutive 100 ms intervals.
- Possible causes -
Poor connection of the interface harness which connects the laser
synchronization detector board and the BiCU board
Laser synchronization detector board out of position
Laser synchronization detector board defective
BiCU board defective
SC324: LD drive current over (A193/A224)
-Definition- [B]
The LD drive board applies more than 100 mA to the LD.
- Possible causes -
LD unit defective (not enough power, due to aging)
Poor connection of the interface harness which connects the LD unit and
the BiCU board
Temperature around the LD unit is too high
SC390: TD sensor error 1 (A193/A224)
-Definition- [B]
The TD sensor outputs less than 0.5V, 20 seconds after the TD sensor initial
setting has been performed.
- Possible causes -
TD sensor abnormal
Poor connection of the PCU
SC391: Development bias leak (A193/A224)
-Definition- [B]
A development bias leak signal is detected.
- Possible causes -
Poor connection of the PCU
High voltage supply board defective