1.2 PERIODIC SERVICE CALL

The periodic service call notifies the service station of the machine's
condition. The call is made at a time interval programmed in the following
RAM addresses:
Call interval: 01 through 15 month(s) (BCD)
00: Periodic Service Call Disabled
Date and time of the next call
Year: last two digits of the year (BCD)
Month: 01 through 12 (BCD)
Day: 01 through 31 (BCD)
Hour: 00 through 23 (BCD)
To change these settings after programming, change the call interval. The
machine then automatically changes the remaining parameters by referring to
the interval and the current date and time.

1.3 PM CALL

If PM alarm is enabled by the base copier's SP mode and PM call is enabled
by system switch 01, the machine will make an automatic service call when
the base copier's PM counter reaches the PM interval.
Cross reference
PM service call on/off: System switch 01, bit 0
PM alarm on/off: Copier SP mode 5-501-2 (default: enabled)
PM interval: Copier SP mode 5-501-1 (default: 45k prints)

1.4 EFFECTIVE TERM OF SERVICE CALLS

If a time limit for the effectiveness of service calls is programmed, the
machine stops making automatic service calls after the time limit.
Program the time limit at the following addresses. This function is disabled
when all of these addresses are 00(H).
Year: last two digits of the year (BCD)
Month: 01 through 12 (BCD)
Day: 01 through 31 (BCD)
(A639)
Parameters
2-3
AUTOMATIC SERVICE CALLS
Address (H)
480379
48037A
48037B
48037C
48037D
Address (H)
480383
480384
480385