Rev. 04/2000
A224 ROM MODIFICATION HISTORY
DESCRIPTION OF MODIFICATION
(Continued form previous page.)
-Copy Quality in duplex mode.
When the quality of the rear copy is poor,
the added transfer current must be
decreased by SP2-301-3. The new table
shows that transfer current can be set to a
lower range.
Current Table (SP2-301-3)
Table No./
0
Paper width
275
14
250~275
16
200~250
18
~200
19
-White copy problem on 1st scanning.
A. Two new SP modes have been added:
1. SP4-916-1: Scanner Lamp OFF counter
default: 120min
range: 0-300min
2. SP4-916-2 Scanner lamp warm-up time
defalt: 200ms
range:0-500ms
If the scanner lamp remains off for 120min
or longer in between the first and second
scans of each job, the machine will allow
the scanner 120ms for warm-up (default).
B. When the scanner lamp is turned on for
the first time after the main power switch
has been turned on, the machine allows
the scanner 300ms for warm-up.
SM
(Copier Section)
FIRMWARE
LEVEL
A2245532N
Table No./
1
2
3
Paper width
16
18
20
18
20
22
20
22
24
21
23
25
Default
Setting
A2245532Q
13-79
ROM HISTORY
SERIAL
NUMBER
September '98
New Table (SP2-301-3
0
1
275
8
11
250~275
10
13
200~250
12
15
~200
14
17
March '99
FIRMWARE
VERSION
1.34
)
2
3
14
16
16
18
18
20
19
21
Default
Setting
1.36
A224