Flow Interval - H3C S3100 Series Command Manual

Hide thumbs Also See for S3100 Series:
Table of Contents

Advertisement

Command Manual (For Soliton) – Port Basic Configuration
H3C S3100 Series Ethernet Switches

1.1.13 flow interval

Syntax
flow-interval interval
undo flow-interval
View
Ethernet port view
Parameter
Interval: Interval (in seconds) to perform statistics on port information. This argument
ranges from 5 to 300 (in step of 5) and is 300 by default.
Description
Use the flow-interval command to set the interval to perform statistics on port
information.
Use the undo flow-interval command to restore the default interval.
By default, this interval is 300 seconds.
When you use the display interface interface-type interface-number command to
display the information of a port, the system performs statistical analysis on the traffic
flow passing through the port during the specified interval and displays the average
rates in the interval. For example, if you set the interval to 100 seconds, the displayed
information is as follows:
Last 100 seconds input:
Last 100 seconds output:
Related command: display interface.
Example
# Set the interval to perform statistics on the Ethernet1/0/1 port to 100 seconds.
<Sysname> system-view
System View: return to User View with Ctrl+Z.
[Sysname] interface ethernet 1/0/1
[Sysname-Ethernet1/0/1] flow-interval 100