Info-Center Trapbuffer - H3C S3100 Series Command Manual

Hide thumbs Also See for S3100 Series:
Table of Contents

Advertisement

Command Manual (For Soliton) – Information Center
H3C S3100 Series Ethernet Switches
# If you configure to add the UTC time zone in the time stamp, the system information is
output as follows:
%Dec
VTY(1.1.0.2) in unit1 login

1.1.19 info-center trapbuffer

Syntax
info-center trapbuffer [ channel { channel-number | channel-name } | size
buffersize ]*
undo info-center trapbuffer [ channel | size ]
View
System view
Parameter
size: Sets the size of the trap buffer.
buffersize: Size of the trap buffer, represented by the number of messages it holds. It
ranges from 0 to 1,024 and defaults to 256.
channel: Sets the channel through which information is output to the trap buffer.
channel-number: Channel number, ranging from 0 to 9, corresponding to the 10
channels of the system.
channel-name: Channel name. By default, the name of channel 0 to channel 9 is (in
turn) console, monitor, loghost, trapbuffer, logbuffer, snmpagent, channel6,
channel7, channel8, channel9.
Description
Use the info-center trapbuffer command to enable information output to the trap
buffer.
Use the undo info-center trapbuffer command to disable information output to the
trap buffer.
By default, information output to the trap buffer is enabled with channel 3 (trapbuffer) as
the default channel and a maximum buffer size of 256.
This command takes effect only after the information center function is enabled.
Related command: info-center enable, display info-center.
with utc
log - date, trap - date, debug - boot
8 10:12:21:708 2006 [GMT+08:00:00] Sysname SHELL/5/LOGIN:- 1 -
Chapter 1 Information Center Configuration
1-20