Table 1-2 Severity level defined in the information center
Severity
emergencies
alerts
critical
errors
warnings
notifications
informational
debugging
size buffersize: Specifies the size of the log buffer (number of messages the log buffer
holds) you want to display. The buffersize argument ranges from 1 to 1,024 and
defaults to 512.
|: Filters output log information with a regular expression.
begin: Displays the line that matches the regular expression and all the subsequent
lines.
exclude: Displays the log information excluding the specified characters.
include: Displays the log information including the specified characters.
regular-expression: Regular expression.
Description
Use the display logbuffer command to display the status of the log buffer and the
records in the log buffer.
Example
# Display the status of the log buffer and the records in the log buffer.
<Sysname> display logbuffer
Logging buffer configuration and contents:enabled
Allowed max buffer size : 1024
Actual buffer size : 512
Channel number : 4 , Channel name : logbuffer
Dropped messages : 0
Overwritten messages : 0
Current messages : 91
%Jun 19 18:03:24:55 2006 Sysname IC/7/SYS_RESTART:
System restarted --
Severity value
1
The system is unavailable.
2
Information that demands prompt reaction
3
Critical information
4
Error information
5
Warnings
6
Normal information that needs to be noticed
7
Informational information to be recorded
8
Information generated during debugging