Display Transceiver Interface - H3C S3100 Series Command Manual

Hide thumbs Also See for S3100 Series:
Table of Contents

Advertisement

Command Manual (For Soliton) – System Maintenance and Debugging
H3C S3100 Series Ethernet Switches
Table 3-7 Description on the fields of display transceiver diagnosis interface
transceiver diagnostic information
Current diagnostic parameters
Temp.(°C)
Voltage(V)
Bias(mA)
RX power(dBM)
TX power(dBM)

3.1.11 display transceiver interface

Syntax
display transceiver interface [ interface-type interface-number ]
View
Any view
Parameters
interface-type interface-number: Interface type and interface number.
Description
Use the display transceiver interface command to display main parameters of a
single or all transceivers.
Examples
# Display main parameters of the pluggable transceiver on interface GigabitEthernet
1/1/2.
<Sysname> display transceiver interface gigabitethernet 1/1/2
GigabitEthernet1/1/2 transceiver information:
Transceiver Type
Connector Type
Wavelength(nm)
Transfer Distance(km)
Field
3-11
Chapter 3 Device Management
Description
Digital diagnosis information of the
transceiver carried by an interface
Current diagnostic parameters
Digital diagnosis parameter-temperature, in
°C, with the precision to 1°C.
Digital diagnosis parameter-voltage, in V, with
the precision to 0.01 V.
Digital diagnosis parameter-bias current, in
mA, with the precision to 0.01 mA.
Digital diagnosis parameter-RX power, in
dBM, with the precision to 0.01 dBM.
Digital diagnosis parameter-TX power, in
dBM, with the precision to 0.01 dBM.
: 1000_BASE_LX_SFP
: LC
: 1310
: 10(9um)
Commands

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents