Command Manual (For Soliton) – System Maintenance and Debugging
H3C S3100 Series Ethernet Switches
mm/dd/yyyy or yyyy/mm/dd: Reboot date, where yyyy (year) ranges from 2,000 to
2,099, mm (month) ranges from 1 to 12, and the range of dd (day) depends on the
specific month. You cannot set the date 30 days later than the system current date.
Description
Use the schedule reboot at command to schedule a reboot on the current switch and
set the reboot date and time.
Use the undo schedule reboot command to cancel the scheduled reboot.
By default, no scheduled reboot is set on the switch.
Note:
The switch timer can be set to a precision of one minute, that is, the switch will reboot
within one minute after the specified reboot date and time.
After you execute the schedule reboot at command with a specified future date, the
switch will reboot at the specified time with at most one minute delay.
After you execute the schedule reboot at command without specifying a date, the
switch will:
Reboot at the specified time on the current day if the specified time is later than the
current time.
Reboot at the specified time on the next day if the specified time is earlier than the
current time.
After you execute the command, the system will prompt you to confirm. Enter "Y" or "y"
for your setting to take effect, and your setting will overwrite the previous one (if
available).
If you adjust the system time by the clock command after executing the schedule
reboot at command, the schedule reboot at command will be invalid and the
scheduled reboot will not happen.
Related command: reboot, display schedule reboot.
Example
# Suppose the current time is 05:06, schedule a reboot so that the switch reboots at
22:00 on the current day.
<Sysname> schedule reboot at 22:00
Reboot system at 22:00 2000/04/02(in 22 hours and 0 minutes)
confirm?[Y/N]:y
<Sysname>