By default, Rx flow control is disabled on Ethernet interfaces.
With the flow-control receive enable command configured, an interface can receive, but not send flow
control frames. When the interface receives a flow control frame from its peer, it suspends sending
packets to the peer. When traffic congestion occurs on the interface, it cannot send flow control frames
to the peer.
To handle unidirectional traffic congestion on a link, configure the flow-control receive enable command
at one end, and the flow-control command at the other. To enable both ends of the link to handle traffic
congestion, configure the flow-control command at both ends.
Examples
# Enable Rx mode generic flow control on GigabitEthernet 1/0/1.
<Sysname> system-view
[Sysname] interface gigabitethernet 1/0/1
[Sysname-GigabitEthernet1/0/1] flow-control receive enable

flow-interval

Syntax
flow-interval interval
undo flow-interval
View
Ethernet interface view
Default level
2: System level
Parameters
interval: Sets a statistics polling interval, in seconds. It ranges from 5 to 300 and must be a multiple of
5.
Description
Use the flow-interval command to set the interface statistics polling interval.
Use the undo flow-interval command to restore the default interval.
The default interface statistics polling interval depends on your device model.
Examples
# Set the statistics polling interval to 100 seconds on GigabitEthernet 1/0/1.
<Sysname> system-view
[Sysname] interface gigabitethernet 1/0/1
[Sysname-GigabitEthernet1/0/1] flow-interval 100

group-member