SNMP PDUs which had
tooBig error-status
(Maximum packet size
1500)
MIB objects retrieved
successfully
MIB objects altered
successfully
GetRequest-PDU
accepted and processed
GetNextRequest-PDU
accepted and processed
GetBulkRequest-PDU
accepted and processed
GetResponse-PDU
accepted and processed
SetRequest-PDU
accepted and processed
Trap PDUs accepted and
processed
Alternate Response
Class PDUs dropped
silently
Forwarded Confirmed
Class PDUs dropped
silently
Field
The total number of SNMP PDUs which were delivered
to the SNMP protocol entity and for which the value of
the error-status field is `tooBig'.
The total number of MIB objects which have been
retrieved successfully by the SNMP protocol entity as
the result of receiving valid SNMP Get-Request and
Get-Next PDUs.
The total number of MIB objects which have been
altered successfully by the SNMP protocol entity as the
result of receiving valid SNMP Set-Request PDUs.
The total number of SNMP Get-Request PDUs which
have been accepted and processed by the SNMP
protocol entity.
The total number of SNMP Get-Next PDUs which have
been accepted and processed by the SNMP protocol
entity.
The total number of SNMP Get-Bulk PDUs which have
been accepted and processed by the SNMP protocol
entity.
The total number of SNMP Get-Response PDUs which
have been accepted and processed by the SNMP
protocol entity.
The total number of SNMP Set-Request PDUs which
have been accepted and processed by the SNMP
protocol entity.
The total number of SNMP Trap PDUs which have been
accepted and processed by the SNMP protocol entity.
The total number of GetRequest-PDUs,
GetNextRequest-PDUs, GetBulkRequest-PDUs,
SetRequest-PDUs, and InformRequest-PDUs delivered
to the SNMP entity which were silently dropped
because the size of a reply containing an alternate
Response-PDU with an empty variable-bindings field
was greater than either a local constraint or the
maximum message size associated with the originator
of the request.
The total number of Confirmed Class PDUs (such as
GetRequest-PDUs, GetNextRequest-PDUs,
GetBulkRequest-PDUs, SetRequest-PDUs, and
InformRequest-PDUs) delivered to the SNMP entity
which were silently dropped because the transmission
of the (possibly translated) message to a proxy target
failed in a manner (other than a time-out) such that no
Response Class PDU (such as a Response-PDU) could
be returned.