Enable Snmp Trap Updown - H3C S3100 Series Command Manual

Hide thumbs Also See for S3100 Series:
Table of Contents

Advertisement

Command Manual (For Soliton) – SNMP-RMON
H3C S3100 Series Ethernet Switches
Field
Storage-type
UserStatus

1.1.9 enable snmp trap updown

Syntax
enable snmp trap updown
undo enable snmp trap updown
View
Ethernet port view, interface view
Parameters
None
Description
Use the enable snmp trap updown command to enable the sending of port/interface
linkUp/linkDown traps.
Use the undo enable snmp trap updown command to disable the sending of
linkUp/linkDown traps.
By default, the sending of port/interface linkUp/linkDown traps is enabled.
Note that you need to enable the generation of port/interface linkUp/linkDown traps
both on the port/interface and globally if you want a port/interface to generate
port/interface linkUp/linkDown traps when the state of the port/interface changes.
To enable this function on a port/interface, use the enable snmp trap updown
command; to enable this function globally, use the snmp-agent trap enable
[ standard [ linkdown | linkup ] * ] command. By default, both are enabled.
Examples
# Enable the port Ethernet 1/0/1 to send linkUp/linkDown SNMP traps to the NMS
whose IP address is 10.1.1.1 using the community name public.
<Sysname> system-view
Storage type, which can be:
volatile: Information will be lost if the system is rebooted
nonVolatile: Information will not be lost if the system is
rebooted
permanent: Modification is permitted, but deletion is
forbidden
readOnly: Read only, that is, no modification, no deletion
other: Other storage types
SNMP user status
1-12
Chapter 1 SNMP Configuration Commands
Description