Problems with Manual Backup

Display Shows "Insert Valid Card" in
System Programming Mode
Possible Cause: The system did not detect a valid Backup/Restore PC Card when
you tried to do a manual backup using Backup Programming—Manual (#124).
What to do: Power down the system, insert a valid Backup/Restore PC Card in PC
Card Slot 2 of the PARTNER ACS processor module, and reapply power to the
system. Restart the procedure.
Display Shows "Card is Write Protected" in
System Programming Mode
Possible Cause: You tried to do a manual backup using Backup Programming—
Manual (#124), but the Backup/Restore PC Card in the PC Card slot is
write-protected.
What to do: Using the end of a paper clip or another pointed object, gently push
the write-protect tab upward to the nonprotected position (see
the procedure again. (You do not need to remove the card from the processor to
slide the write-protect tab up.)
Slide the switch on the PC card
up to the nonprotected position
Figure 6-7. Write-Protect Tab on a Backup/Restore PC Card
Display Shows "System Busy" in
System Programming Mode
Possible Cause: An automatic or manual backup was in progress at the time you
requested a manual backup.
What to do: Exit the procedure and retry the manual backup after a few minutes.