1200 baud
SMDR Output
Format
8 data bits
XON/XOFF protocol
Line feeds
No parity
2 stop bits
Carriage return
Environmenta
Mount on a wall at least 2 feet (0.6 meters) from the floor (wall mounting required)
l
Locate within 5 feet (1.5 meters) of the network interface jacks and a properly grounded
Requirements
electrical outlet not controlled by a switch, using supplied 7-foot (2.1-meter) cords
-Control Unit
Operating temperature 32° to + 104°F (0° to + 40°C), not in direct sunlight
Humidity 15%-90%, noncondensing
For proper ventilation and easy replacement of modules, provide the following minimum
clearance around the control unit:
—5-Slot carrier: 1 foot (0.3 meter) clearance at the top and sides and 2 feet (0.6 meter) at
the front and bottom
—2-Slot carrier or Standalone ACS processor module: 1 foot (0.3 meter) clearance at the
front, top and right side, and 2 feet (0.6 meter) at the bottom and left side
Locate in an area free of excess moisture, corrosive gases, dust, and chemicals
Electrical
U.S. and Canada: 90-264 VAC, 47-63 Hz, 3-prong outlet separate ground, separately
fused at 15 Amps
Requirements
-Control Unit
Other countries: 90-264 VAC (220 VAC fused at 10 Amps)
Grounding to comply with Underwriters Laboratories (UL) 1459:
A. An insulated grounding conductor that is not smaller in size and equivalent in
B. The grounding conductor mentioned in item A is to be connected to ground at the
C. The attachment-plug receptacles in the vicinity of the product or system are all to be of
Requirements
Installation of a telephone or other standard (tip/ring) device in another building requires
the following In-Range-Out-Of-Building (IROB) protectors to protect the control unit and
for Out-of-
device from electrical surges:
Building
Installations
—System phone: two Lucent Technologies IROB protectors
—Standard phone: one Lucent Technologies IROB protector plus one carbon block
protector
Installation of a Contact Closure Adjunct controlled device outside the building requires a
Lucent Technologies 146G Surge Protector-SCL/8 to protect the control unit from
electrical surges
A-4
Specifications
insulation material and thickness to the grounded and ungrounded branch circuit
supply conductors, except that it is green with or without one or more yellow stripes, is
to be installed as part of the circuit that supplies the product or system
service equipment
a grounding type, and the grounding conductors serving these receptacles are to be
connected to earth ground at the service equipment