System phones: Lucent Technologies SYSTIMAX® Bulk Nonplenum (DIW) cable, Lucent
Wiring
Technologies SYSTIMAX Bulk Plenum (HALAR/HALAR) cable, or at least 2-pair (4-wire)
star ("home run" not "loop")
Other standard telecommunications equipment (single-line phones, fax machines,
answering machines, etc.): 1-pair (2-wire) mounting cords (Lucent Technologies D2R
mounting cords recommended)
Bridging adapter: Lucent Technologies 267F2
Range: 1,000 feet (305 meters) for system phones; 3,000 feet (915 meters) for standard
devices
Safety
U.S.: Meets UL 1459 Issue 2
Requirements
Canada: Meets CSA C22.2, 225
All other countries: Meets IEC950 Second Edition and EN60950 Second Edition
Government
U.S.:
Approvals
and Local
Phone
Company
Information
Canada:
FCC Part 68
FCC registration number (U.S.): See the label on the side of the control unit.
FCC Part 15:
Class A:
5-Slot Configuration
2-Slot Configuration with 308EC or PARTNER MAIL VS
Class B:
PARTNER Advanced Communications System Standalone Configuration
2-Slot Configuration with 200, 206, or 400 module plus ACS processor
module
REN (outside line jack): 0.9A per line jack
Jack type: RJ11C
Loop start lines
IC CP01, Issue 7
IC registration number (Canada): See the label on the side of the control unit.
IC CS03, Issues 6 & 7
Load Number = 7
Loop start lines
Specifications