Lucent Technologies PARTNER Advanced Communications System Programming And Use Instructions page 437

Releases 1.0, 1.1, and 2.0
Hide thumbs Also See for PARTNER Advanced Communications System:
Table of Contents

Advertisement

68306 16 Mhz processor
Processor
Module
256Kbyte RAM
Specifications
512Kbyte FLASH ROM
Custom VLSI DSP ASIC—16bit, 52 Mhz
—VLSI = Very Large Scale Integration
—DSP = Digital Signal Processor
—ASIC = Application Specific Integrated Circuit
Extension
Ringing voltage: +5VDC, -140 VDC peak to peak; trapezoidal wave shaping
Jack
35- to 38-Volt talk battery
Specifications
Ringing frequency: 20 Hz
(206 module)
Extension
Ringing voltage: +55VRMS Balanced ringing within a trapezoidal wave shaping
Jack
38- to 42-Volt talk battery
Specifications
Ringing frequency: 20 HZ
(ACS
Processor
and 308EC
module)
PAGE Jack
Draws current on inner wire pair
Specifications
Provides paging contact closure on outer wire pair
600 Ohm impedance
MUSIC ON
Accepts 2 Volts at 50 Kohms maximum input
HOLD Jack
0 - 18 dB attenuation
Specifications
CONTACT
Operates up to 150 feet (45.72 meters) from control unit using 24 gauge solid conductor
wire if 2 Contact Closures used; up to 800 feet (243.84 meters) from control unit using 24
CLOSURE
gauge solid conductor wire if only 1 Contact Closure used
Adjunct Jack
Specifications
Install the Contact Closure Adjunct in the same building as the control unit; cannot be
installed out-of-doors
Has three terminals per Contact Closure, providing a normally open and normally closed
function for each Contact Closure
Maximum contact voltages and current:
—30 VAC, 1 Amp
—50 VDC, 1 Amp
Specifications