Problems With Automatic Backup - Lucent Technologies PARTNER Advanced Communications System Programming And Use Instructions

Releases 1.0, 1.1, and 2.0
Hide thumbs Also See for PARTNER Advanced Communications System:
Table of Contents

Advertisement

Problems with Automatic Backup

Display Shows "Backup Failed:Insert Card" at
Idle Extensions 10 and 11
Possible Cause: The system did not detect a valid Backup/Restore PC Card while
trying to do an automatic backup.
What to do: Power down the system, insert a valid Backup/Restore PC Card in PC
Card Slot 2 of the PARTNER ACS processor module, and reapply power to the
system. The backup is rescheduled for the next day at 2:00 a.m.
Enter Backup Programming—Automatic (#123) and select Option 3 to clear the
alarm display (see
Display Shows "Backup Failed:Write Prot" at
Idle Extensions 10 and 11
Possible Cause: The Backup/Restore PC Card in the PC Card slot is
write-protected, and an automatic backup was attempted.
What to do: Using the end of a paper clip or another pointed object, push the
write-protect tab upward to the nonprotected position (see
need to remove the card from the processor to slide the write-protect tab up.The
backup is rescheduled for the next day at 2:00 a.m.
Slide the switch on the PC card
up to the nonprotected position
Figure 6-6. Write-Protect Tab on a Backup/Restore PC Card
Enter Backup Programming—Automatic (#123) and select Option 3 to clear the
alarm display (see
''Clearing a Backup-Failure Alarm'' on page
''Clearing a Backup-Failure Alarm'' on page
6-7).
Figure
6-6). You do not
6-7).
6-25
Troubleshooting