ABB Relion 650 Series Technical Manual page 601

Hide thumbs Also See for Relion 650 Series:
Table of Contents

Advertisement

1MRK 506 326-UUS B
19.9
Environmental conditions and tests
Table 566: Environmental conditions
Description
Operating temperature range
Short-time service temperature range
Relative humidity
Atmospheric pressure
Altitude
Transport and storage temperature range
Table 567: Environmental tests
Description
Cold tests
Dry heat tests
Damp heat
tests
Line distance protection REL650
Technical manual
Type test value
operation
96 h at -25ºC
16 h at -40ºC
storage
96 h at -40ºC
operation
16 h at +70ºC
storage
96 h at +85ºC
steady state
240 h at +40ºC
humidity 93%
cyclic
6 cycles at +25 to +55ºC
humidity 93...95%
© Copyright 2011 ABB Power Grids. All rights reserved
Value
-25...+55ºC (continuous)
-40...+70ºC (<16h)
Note: Degradation in MTBF and HMI performance
outside the temperature range of -25...+55ºC
<93%, non-condensing
12.47...15.37 psi (86...106 kPa)
up to 6561.66 feet (2000 m)
-40...+85ºC
Reference
IEC 60068-2-1/ANSI C37.90-2006
(chapter 4)
IEC 60068-2-2/ANSI C37.90-2006
(chapter 4)
IEC 60068-2-78
IEC 60068-2-30
Section 19
Technical data
GUID-8D1EE1BB-C9EF-4184-BB4D-AB32B86DBFCE v3
595

Advertisement

Table of Contents
loading

This manual is also suitable for:

Rel650

Table of Contents