ABB REL670 2.2 IEC Manuals
Manuals and User Guides for ABB REL670 2.2 IEC. We have
1
ABB REL670 2.2 IEC manual available for free PDF download: Applications Manual
ABB REL670 2.2 IEC Applications Manual (908 pages)
RELION 670 SERIES Line distance protection Version 2.2 IEC
Brand:
ABB
| Category:
Protection Device
| Size: 15.04 MB
Table of Contents
Table of Contents
7
Section 1 Introduction
33
This Manual
33
Intended Audience
33
Product Documentation
34
Product Documentation Set
34
Document Revision History
35
Related Documents
36
Document Symbols and Conventions
36
Symbols
36
Document Conventions
37
IEC 61850 Edition 1 / Edition 2 Mapping
38
Section 2 Application
47
General IED Application
47
Main Protection Functions
49
Back-Up Protection Functions
50
Control and Monitoring Functions
52
Communication
61
Basic IED Functions
63
Section 3 Configuration
65
Introduction
65
Description of Configuration REL670
66
Introduction
66
Description of Configuration A41
66
Description of Configuration A42
67
Description of Configuration B42
68
Description of Configuration D42
69
Section 4 Analog Inputs
71
Introduction
71
Setting Guidelines
71
Setting of the Phase Reference Channel
72
Example
72
Setting of Current Channels
72
Example 1
73
Example 2
73
Example 3
74
Examples on How to Connect, Configure and Set CT Inputs for most Commonly Used CT Connections
78
Phase CT Set to the IED
79
Example How to Connect Delta Connected Three-Phase CT Set to the IED
84
Example How to Connect Single-Phase CT to the IED
87
Relationships between Setting Parameter Base Current, CT Rated Primary Current and Minimum Pickup of a Protection IED
89
Examples How to Connect, Configure and Set VT Inputs for most Commonly Used VT Connections
90
Examples on How to Connect a Three Phase-To-Earth Connected VT to the IED
91
Example on How to Connect a Phase-To-Phase Connected VT to the IED
93
Example on How to Connect an Open Delta VT to the IED for High Impedance Earthed or Unearthed Networks
95
For Low Impedance Earthed or Solidly Earthed Power Systems
98
Section 5 Local HMI
101
Display
102
Leds
104
Keypad
105
Local HMI Functionality
107
Parameter Management
108
Front Communication
109
C37.118 Phasor Measurement Data Streaming Protocol Configuration PMUCONF
111
Short Guidance for Use of TCP
112
Short Guidance for Use of UDP
113
Protocol Reporting Via IEEE 1344 and C37.118 PMUREPORT
115
Operation Principle
118
Frequency Reporting
119
Reporting Filters
121
Scaling Factors for ANALOGREPORT Channels
122
PCM600 Application Configuration Tool (ACT)
124
Setting Guidelines
130
High Impedance Differential Protection, Single Phase HZPDIF
135
The Basics of the High Impedance Principle
136
Connection Examples for High Impedance Differential Protection
142
Connections for 1Ph High Impedance Differential Protection HZPDIF
143
Setting Guidelines
144
T-Feeder Protection
145
Tertiary Reactor Protection
148
Alarm Level Operation
151
Distance Measuring Zone, Quadrilateral Characteristic for Series Compensated Lines ZMCPDIS, ZMCAPDIS, ZDSRDIR
153
System Earthing
154
Fault Infeed from Remote End
155
Load Encroachment
156
Long Transmission Line Application
157
Parallel Line Application with Mutual Coupling
158
Tapped Line Application
165
Series Compensation in Power Systems
168
Challenges in Protection of Series Compensated and Adjacent Power Lines
175
Impact of Series Compensation on Protective IED of Adjacent Lines
187
Distance Protection
188
Setting Guidelines
195
Setting of Zone1
196
Setting of Reverse Zone
197
Series Compensated and Adjacent Lines
198
Setting of Zones for Parallel Line Application
203
Setting of Reach in Resistive Direction
204
Load Impedance Limitation, Without Load Encroachment Function
205
Load Impedance Limitation, with Load Encroachment Function Activated
207
Phase Selection, Quad, Fixed Angle, Load Encroachment FDPSPDIS
208
Resistive Reach with Load Encroachment Characteristic
214
Minimum Operate Currents
215
System Earthing
216
Fault Infeed from Remote End
219
Load Encroachment
220
Short Line Application
221
Long Transmission Line Application
222
Parallel Line Application with Mutual Coupling
223
Tapped Line Application
229
Setting Guidelines
232
Setting of Reverse Zone
233
Setting of Zones for Parallel Line Application
234
Setting of Reach in Resistive Direction
235
Load Impedance Limitation, Without Load Encroachment Function
236
Load Encroachment, Quadrilateral Characteristic Function Activated
238
Setting of Timers for Distance Protection Zones
241
System Earthing
242
Fault Infeed from Remote End
245
Load Encroachment
246
Short Line Application
248
Parallel Line Application with Mutual Coupling
249
Tapped Line Application
254
Setting Guidelines
255
Setting of Zone 1
256
Setting of Zone 3
257
Consideration of Zero Sequence Mutual Coupling for Parallel Circuits
263
Load Impedance Limitation, with Load Encroachment Function Activated
265
Setting of Minimum Operate Currents
266
Full-Scheme Distance Protection, Quadrilateral for Earth Faults ZMMPDIS, ZMMAPDIS
267
Fault Infeed from Remote End
271
Short Line Application
272
Long Transmission Line Application
273
Tapped Line Application
279
Setting Guidelines
282
Setting of Reverse Zone
283
Setting of Zones for Parallel Line Application
284
Setting of Reach in Resistive Direction
285
Load Impedance Limitation, Without Load Encroachment Function
286
Load Impedance Limitation, with Load Encroachment Function Activated
287
Setting of Timers for Distance Protection Zones
288
Mho Impedance Supervision Logic ZSMGAPC
291
Faulty Phase Identification with Load Encroachment FMPSPDIS
292
Setting Guidelines
293
Load Encroachment
294
Distance Protection Zone, Quadrilateral Characteristic, Separate Settings ZMRPDIS, ZMRAPDIS and ZDRDIR
295
Identification
296
Fault Infeed from Remote End
300
Load Encroachment
301
Short Line Application
302
Parallel Line Application with Mutual Coupling
303
Tapped Line Application
310
Setting Guidelines
312
Setting of Reverse Zone
313
Setting of Zones for Parallel Line Application
314
Setting of Reach in Resistive Direction
315
Load Impedance Limitation, Without Load Encroachment Function
316
Activated
318
Phase Selection, Quadrilateral Characteristic with Settable Angle FRPSPDIS
319
Load Encroachment Characteristics
324
Phase-To-Earth Fault in Forward Direction
325
Phase-To-Earth Fault in Reverse Direction
327
Phase-To-Phase Fault in Forward Direction
328
Setting Guidelines
330
Minimum Operate Currents
331
Setting Guidelines
332
Resistive Reach with Load Encroachment Characteristic
337
Minimum Operate Currents
338
Fault Infeed from Remote End
342
Load Encroachment
343
Short Line Application
344
Parallel Line Application with Mutual Coupling
345
Tapped Line Application
351
Setting Guidelines
353
Setting of Zone 1
354
Setting of Reverse Zone
355
Setting the Reach with Respect to Load
357
Zone Reach Setting Lower than Minimum Load Impedance
358
Zone Reach Setting Higher than Minimum Load Impedance
360
Other Settings
361
ZMMMXU Settings
364
High Speed Distance Protection for Series Compensated Lines ZMFCPDIS
365
Fault Infeed from Remote End
368
Load Encroachment
369
Short Line Application
370
Parallel Line Application with Mutual Coupling
371
Tapped Line Application
377
Series Compensation in Power Systems
379
Steady State Voltage Regulation and Increase of Voltage Collapse Limit
380
Increase in Power Transfer
381
Voltage and Current Inversion
382
Impact of Series Compensation on Protective IED of Adjacent Lines
390
Distance Protection
391
Underreaching and Overreaching Schemes
392
Setting Guidelines
398
Setting of Zone 1
399
Setting of Reverse Zone
400
Series Compensated and Adjacent Lines
401
Setting of Zones for Parallel Line Application
405
Setting of Reach in Resistive Direction
406
Load Impedance Limitation, Without Load Encroachment Function
407
Zone Reach Setting Higher than Minimum Load Impedance
409
Parameter Setting Guidelines
410
ZMMMXU Settings
412
Power Swing Detection ZMRPSB
413
Basic Characteristics
414
Setting Guidelines
415
Power Swing Logic PSLPSCH
422
Setting Guidelines
424
Blocking and Tripping Logic for Evolving Power Swings
428
Pole Slip Protection PSPPPAM
429
Setting Guidelines
432
Setting Example for Line Application
434
Setting Example for Generator Application
438
Out-Of-Step Protection OOSPPAM
442
Setting Guidelines
445
Automatic Switch Onto Fault Logic ZCVPSOF
448
Application
449
Phase Preference Logic PPLPHIZ
451
Setting Guidelines
454
Phase Preference Logic PPL2PHIZ
455
Setting Guidelines
459
Instantaneous Phase Overcurrent Protection PHPIOC
461
Setting Guidelines
462
Meshed Network with Parallel Line
464
Directional Phase Overcurrent Protection, Four Steps OC4PTOC
466
Setting Guidelines
467
Settings for each Step
469
Setting Example
472
Instantaneous Residual Overcurrent Protection EFPIOC
477
Directional Residual Overcurrent Protection, Four Steps EF4PTOC
480
Setting Guidelines
482
Common Settings for All Steps
483
Nd Harmonic Restrain
484
Parallel Transformer Inrush Current Logic
485
Switch Onto Fault Logic
486
Settings for each Step (X = 1, 2, 3 and 4)
487
Line Application Example
489
Four Step Directional Negative Phase Sequence Overcurrent Protection NS4PTOC
494
Setting Guidelines
496
Settings for each Step
497
Common Settings for All Steps
499
Sensitive Directional Residual Overcurrent and Power Protection SDEPSDE
500
Identification
501
Setting Guidelines
502
Thermal Overload Protection, One Time Constant, Celsius Fahrenheit LCPTTR/LFPTTR
511
Setting Guideline
512
Breaker Failure Protection CCRBRF
513
Stub Protection STBPTOC
517
Setting Guidelines
518
Pole Discordance Protection CCPDSC
519
Setting Guidelines
520
Application
521
Setting Guidelines
523
Directional Overpower Protection GOPPDOP
526
Setting Guidelines
528
Broken Conductor Check BRCPTOC
532
Voltage-Restrained Time Overcurrent Protection VRPVOC
533
Base Quantities
534
Setting Guidelines
535
Voltage-Restrained Overcurrent Protection for Generator and Step-Up Transformer
536
Overcurrent Protection with Undervoltage Seal-In
537
Two Step Undervoltage Protection UV2PTUV
539
Setting Guidelines
540
Settings for Two Step Undervoltage Protection
541
Two Step Overvoltage Protection OV2PTOV
542
Application
543
Equipment Protection, such as for Motors, Generators Reactors and Transformers
544
Two Step Residual Overvoltage Protection ROV2PTOV
547
Reactors and Transformersequipment Protection for Transformers
548
Direct Earthed System
549
Settings for Two Step Residual Overvoltage Protection
550
Overexcitation Protection OEXPVPH
552
Setting Guidelines
554
Settings
555
Service Value Report
556
Voltage Differential Protection VDCPTOV
558
Setting Guidelines
560
Loss of Voltage Check LOVPTUV
561
Application
562
Setting Guidelines
563
Underfrequency Protection SAPTUF
565
Overfrequency Protection SAPTOF
566
Application
567
Rate-Of-Change of Frequency Protection SAPFRC
568
General Current and Voltage Protection CVGAPC
571
Current and Voltage Selection for CVGAPC Function
572
Base Quantities for CVGAPC Function
575
Inadvertent Generator Energization
576
Setting Guidelines
577
Negative Sequence Overcurrent Protection
579
Generator Stator Overload Protection in Accordance with IEC or ANSI Standards
581
Generators and Circuit Breaker Head Flashover Protection for Generators
583
Voltage Restrained Overcurrent Protection for Generator and Step-Up Transformer
584
Loss of Excitation Protection for a Generator
585
Multipurpose Filter SMAIHPAC
587
Setting Guidelines
588
Current Circuit Supervision CCSSPVC
593
Fuse Failure Supervision FUFSPVC
594
Setting Guidelines
595
Negative Sequence Based
596
Zero Sequence Based
597
Dead Line Detection
598
Application
599
Setting Guidelines
600
Synchrocheck, Energizing Check, and Synchronizing SESRSYN
601
Synchrocheck
603
Energizing Check
604
Voltage Selection
605
External Fuse Failure
606
Application Examples
607
Single Circuit Breaker with Single Busbar
608
Single Circuit Breaker with Double Busbar, External Voltage Selection
609
Double Circuit Breaker
610
Setting Guidelines
614
Smbrrec
619
Auto Reclosing Operation off and on
623
Start Auto Reclosing from Circuit Breaker Open Information
624
Long Trip Signal
625
First Shot
626
Armode = 1Ph + 1*2/3Ph, 1-Phase, 2-Phase or 3-Phase Reclosing in the First Shot
627
Auto Reclosing Reclaim Timer
628
Lock-Out Initiation
629
Evolving Fault
630
Automatic Continuation of the Auto Reclosing Sequence
631
Auto Recloser Settings
641
Apparatus Control
645
Bay Control QCBAY
649
Switch Controller SCSWI
650
Switches SXCBR/SXSWI
651
Xlnproxy
652
Reservation Function (QCRSV and RESIN)
655
Interaction between Modules
657
Setting Guidelines
659
Bay Control (QCBAY)
660
Switch (SXCBR/SXSWI)
661
Xlnproxy
662
Reservation Input (RESIN)
663
Configuration Guidelines
664
Signals from Bypass Busbar
665
Signals from Bus-Coupler
666
Configuration Setting
668
Interlocking for Bus-Coupler Bay ABC_BC
669
Application
670
Signals from Bus-Coupler
672
Configuration Setting
674
Interlocking for Transformer Bay AB_TRAFO
675
Signals from Bus-Coupler
676
Interlocking for Bus-Section Breaker A1A2_BS
677
Configuration Setting
680
Interlocking for Bus-Section Disconnector A1A2_DC
681
Signals in Double-Breaker Arrangement
684
Signals in 1 1/2 Breaker Arrangement
687
Interlocking for Busbar Earthing Switch BB_ES
688
Signals in Double-Breaker Arrangement
692
Signals in 1 1/2 Breaker Arrangement
693
Interlocking for Double CB Bay DB
694
Configuration Setting
695
Interlocking for 1 1/2 CB BH
696
Logic Rotating Switch for Function Selection and LHMI Presentation SLGAPC
697
Setting Guidelines
698
Setting Guidelines
699
Application
700
Identification
701
Identification
702
Setting Guidelines
704
Scheme Communication Logic for Distance or Overcurrent Protection ZCPSCH
707
Blocking Schemes
708
Delta Blocking Scheme
709
Permissive Schemes
710
Intertrip Scheme
712
Setting Guidelines
713
Permissive Underreaching Scheme
714
Phase Segregated Scheme Communication Logic for Distance Protection ZC1PPSCH
715
Blocking Scheme
717
Intertrip Scheme
719
Permissive Overreach Scheme
720
Weak-End Infeed Logic
721
Setting Guidelines
722
Current Reversal Logic
723
Application
724
Setting Guidelines
725
Local Acceleration Logic ZCLCPSCH
726
Setting Guidelines
727
Scheme Communication Logic for Residual Overcurrent Protection ECPSCH
728
Setting Guidelines
729
Application
730
Weak-End Infeed Logic
731
Weak-End Infeed
732
Direct Transfer Trip Logic
733
Setting Guidelines
734
Identification
735
Compensated over and Undervoltage Protection COUVGAPC
736
Setting Guidelines
738
Sudden Change in Current Variation SCCVPTOC
739
Setting Guidelines
740
Setting Guidelines
741
Zero Sequence Overvoltage Protection LCZSPTOV
742
Negative Sequence Overcurrent Protection LCNSPTOC
743
Zero Sequence Overcurrent Protection LCZSPTOC
744
Three Phase Overcurrent LCP3PTOC
745
Identification
746
Tripping Logic SMPPTRC
747
Three-Phase Tripping
748
Single- And/Or Three-Phase Tripping
749
Single-, Two- or Three-Phase Tripping
750
Example of Directional Data
751
Blocking of the Function Block
753
Application
754
Setting Guidelines
755
Setting Guidelines
756
Fixed Signal Function Block FXDSIGN
758
Boolean 16 to Integer Conversion B16I
759
Boolean to Integer Conversion with Logical Node Representation, 16 Bit BTIGAPC
760
Integer to Boolean 16 Conversion IB16
761
Identification
762
Representation ITBGAPC
763
Elapsed Time Integrator with Limit Transgression and Overflow Supervision TEIGAPC
764
Setting Guidelines
765
Setting Guidelines
766
Comparator for Real Inputs - REALCOMP
767
Setting Example
768
Measurement
769
Zero Clamping
771
Setting Guidelines
772
Setting Examples
775
Gas Medium Supervision SSIMG
781
Setting Guidelines
782
Liquid Medium Supervision SSIML
783
Breaker Monitoring SSCBR
784
Setting Guidelines
787
Event Function EVENT
788
Application
789
Disturbance Report DRPRDRE
790
Setting Guidelines
791
Recording Times
793
Binary Input Signals
794
Analog Input Signals
795
Consideration
796
Logical Signal Status Report BINSTATREP
797
Setting Guidelines
798
Setting Guidelines
799
Connection of Analog Currents
800
Limit Counter L4UFCNT
801
Setting Guidelines
802
Pulse-Counter Logic PCFCNT
805
Function for Energy Calculation and Demand Handling ETPMMTR
806
Setting Guidelines
807
Access Point
809
Redundant Communication
810
Application
811
Setting Guidelines
812
Merging Unit
813
Setting Guidelines
814
Communication Protocols
815
Setting Guidelines
817
Receiving Data
818
IEC/UCA 61850-9-2LE Communication Protocol
819
Setting Guidelines
822
Specific Settings Related to the IEC/UCA 61850-9-2LE Communication
823
Setting Examples for IEC/UCA 61850-9-2LE and Time Synchronization
828
IEC 61850 Quality Expander QUALEXP
833
LON Communication Protocol
834
MULTICMDRCV and MULTICMDSND
835
Identification
836
Setting Guidelines
837
IEC 60870-5-103 Communication Protocol
839
Design
840
Settings
842
Settings for RS485 and Optical Serial Communication
843
Settings from PCM600
844
Function and Information Types
846
DNP3 Communication Protocol
847
Binary Signal Transfer
849
Communication Hardware Solutions
850
Setting Guidelines
851
Authority Status ATHSTAT
857
Change Lock CHNGLCK
858
Denial of Service SCHLCCH/RCHLCCH
859
IED Identifiers TERMINALID
861
Factory Defined Settings
862
Identification
863
Setting Guidelines
864
Application
865
Setting Guidelines
866
Application
867
Frequency Values
868
Setting Guidelines
869
Test Mode Functionality TESTMODE
874
Setting Guidelines
876
Setting Guidelines
877
Synchronization
878
Process Bus IEC/UCA 61850-9-2LE Synchronization
880
Section 25 Requirements
883
Conditions
885
Fault Current
886
General Current Transformer Requirements
887
Distance Protection
888
Breaker Failure Protection
890
PX, PXR (and Old IEC 60044-6, Class TPS and Old British Standard, Class X)
891
Voltage Transformer Requirements
892
PTP Requirements
893
IEC/UCA 61850-9-2LE Merging Unit Requirements
894
Section 26 Glossary
897
Advertisement
Advertisement
Related Products
ABB REL650 series
ABB Relion REL670 2.1 IEC
ABB REL650 A11
ABB REL650 A12
ABB RELION 650 SERIES
ABB RELION REM615
ABB REL 531
ABB REL 501-C1 2.5
ABB REL 511-C1 2.5 Series
ABB Relion REG650
ABB Categories
Industrial Equipment
Controller
Measuring Instruments
Battery Charger
DC Drives
More ABB Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL