Scheme communication
Name
CSOR
CSUR
CR
CR_GUARD
Table 273: ZCPSCH (85) Output signals
Name
TRIP
CS
CRL
LCG
11.1.5
Settings
Table 274: ZCPSCH (85) Group settings (basic)
Name
Values (Range)
Operation
Disabled
Enabled
SchemeType
Disabled
Intertrip
Permissive UR
Permissive OR
Blocking
tCoord
0.000 - 60.000
tSendMin
0.000 - 60.000
Table 275: ZCPSCH (85) Group settings (advanced)
Name
Values (Range)
Unblock
Disabled
NoRestart
Restart
tSecurity
0.000 - 60.000
340
Type
Default
Description
BOOLEAN
0
Signal to be used for channel start with overreaching pilot
schemes
BOOLEAN
0
Signal to be used for channel start with underreaching pilot
schemes
BOOLEAN
0
Channel receive input signal from communications apparatus/
module for pilot communication scheme logic
BOOLEAN
0
Carrier channel guard input signal
Type
Description
BOOLEAN
Trip by pilot communication scheme logic
BOOLEAN
Pilot channel start signal
BOOLEAN
Channel receive signal output from communication scheme logic
BOOLEAN
Loss of channel guard signal output from communication scheme
logic
Unit
Step
-
-
-
-
s
0.001
s
0.001
Unit
Step
-
-
s
0.001
© Copyright 2011 ABB Power Grids. All rights reserved
Default
Description
Disabled
Disable/Enable Operation
Permissive UR
Scheme type
0.035
Communication scheme channel
coordination time
0.100
Minimum duration of a carrier send signal
(carrier continuation)
Default
Description
Disabled
Operation mode of unblocking logic
0.035
Security timer for loss of carrier guard
detection