ABB Relion 650 Series Technical Manual page 454

Hide thumbs Also See for Relion 650 Series:
Table of Contents

Advertisement

Section 13
Monitoring
Name
Values (Range)
UnderTrigOp36
Disabled
Enabled
UnderTrigLe36
0 - 200
OverTrigOp36
Disabled
Enabled
OverTrigLe36
0 - 5000
NomValue37
0.0 - 999999.9
UnderTrigOp37
Disabled
Enabled
UnderTrigLe37
0 - 200
OverTrigOp37
Disabled
Enabled
OverTrigLe37
0 - 5000
NomValue38
0.0 - 999999.9
UnderTrigOp38
Disabled
Enabled
UnderTrigLe38
0 - 200
OverTrigOp38
Disabled
Enabled
OverTrigLe38
NomValue39
UnderTrigOp39
UnderTrigLe39
OverTrigOp39
OverTrigLe39
NomValue40
UnderTrigOp40
UnderTrigLe40
OverTrigOp40
OverTrigLe40
448
Unit
-
%
-
%
-
-
%
-
%
-
-
%
-
0 - 5000
%
0.0 - 999999.9
-
Disabled
-
Enabled
0 - 200
%
Disabled
-
Enabled
0 - 5000
%
0.0 - 999999.9
-
Disabled
-
Enabled
0 - 200
%
Disabled
-
Enabled
0 - 5000
%
© Copyright 2011 ABB Power Grids. All rights reserved
Step
Default
-
Disabled
1
50
-
Disabled
1
200
0.1
0.0
-
Disabled
1
50
-
Disabled
1
200
0.1
0.0
-
Disabled
1
50
-
Disabled
1
200
0.1
0.0
-
Disabled
1
50
-
Disabled
1
200
0.1
0.0
-
Disabled
1
50
-
Disabled
1
200
1MRK 506 326-UUS B
Description
Use under level trigger for analog channel
36 (on) or not (off)
Under trigger level for analog channel 36 in
% of signal
Use over level trigger for analog channel 36
(on) or not (off)
Over trigger level for analog channel 36 in
% of signal
Nominal value for analog channel 37
Use under level trigger for analog channel
37 (on) or not (off)
Under trigger level for analog channel 37 in
% of signal
Use over level trigger for analog channel 37
(on) or not (off)
Over trigger level for analog channel 37 in
% of signal
Nominal value for analog channel 38
Use under level trigger for analog channel
38 (on) or not (off)
Under trigger level for analog channel 38 in
% of signal
Use over level trigger for analog channel 38
(on) or not (off)
Over trigger level for analog channel 38 in
% of signal
Nominal value for analog channel 39
Use under level trigger for analog channel
39 (on) or not (off)
Under trigger level for analog channel 39 in
% of signal
Use over level trigger for analog channel 39
(on) or not (off)
Over trigger level for analog channel 39 in
% of signal
Nominal value for analog channel 40
Use under level trigger for analog channel
40 (on) or not (off)
Under trigger level for analog channel 40 in
% of signal
Use over level trigger for analog channel
40 (on) or not (off)
Over trigger level for analog channel 40 in
% of signal
Line distance protection REL650
Technical manual