3 Maintenance

3.4.3 Cleaning the Fan unit

3.4.3 Cleaning the Fan unit
Overview
Use this section to clean the fan unit.
Location
en0500001924
A
B
C
Required equipment
Equipment
Standard toolkit
DressPack/SpotPack
Vacuum cleaner
Maintenance procedure
1
2
3
Continues on next page
216
Fan holder with fan
Fan casing
Attachment screws M5x9, Fastite screw (4 pcs)
Action
DANGER
Before any work inside the cabinet, please
observe the safety information in the sec-
tion DANGER - Make sure that the main
power has been switched off in the product
manual for the IRC5 controller.
Remove the attachment screws holding the
fan casing.
Disconnect the fan connector.
© Copyright 2007-2018 ABB. All rights reserved.
Article number
Note
3HAC17290-7
The contents are defined in section
Toolkits, DressPack/SpotPack on
page
-
Note
Shown in the section
Screw M5x9 Fastite (4 pcs)
Product manual - DressPack/SpotPack IRB 6640
335.
Location on page 216
3HAC028638-001 Revision: K