ABB DressPack IRB 6640 Product Manual page 252

Table of Contents

Advertisement

4 Repair
4.2.8 Replacement process cable package IRBDP SW4 UI (IRB66X0ID)
Continued
Continued removal - if the process cable package is scrap
The procedure below details how to continue the removal procedure if the process
cable package is scrap.
1
2
3
Continues on next page
252
Note
Even if the process cable package is being handled as scrap, it is still important
not to damage the motor cable in the process!
Action
Front:
Cut off the R3.WELD connector, the
Harting connector (R3.CP/CS/CBUS)
and the R3.PROC1-5 connector.
Front:
Remove the bearing at the holder back,
M6x30 screws (4 pcs) and washers.
Front:
Remove the bearing holders M6x30
screws (2 pcs).
© Copyright 2007-2018 ABB. All rights reserved.
Note
C
B
A
E
xx0500002010
Parts:
A: Holder back
B: Washer (4 pcs)
C: Hex socket head cap screw M6x30
(4 pcs)
D: Deep groove ball bearing
E: Bearing holder (2 pcs)
Product manual - DressPack/SpotPack IRB 6640
3HAC028638-001 Revision: K
D

Advertisement

Table of Contents
loading

This manual is also suitable for:

Spotpack irb 6640

Table of Contents