4
5
Product manual - DressPack/SpotPack IRB 6640
3HAC028638-001 Revision: K
2.2.7 Fitting the attachments of IRBDP SW6 & MH6 UI/LE (Lean ID)
Action
Fit the tube guiding ring in the cover.
Fit the cover with the tube guiding ring fit-
ted, on the tube and secure it to the arm-
house cover.
Lock screws with locking liquid (Loctite
243).
Note
Check that the tube is being fitted correctly
in both ends, when fitting the cover.
© Copyright 2007-2018 ABB. All rights reserved.
2 Installation
Note
xx1200000044
Attachment screws:
Pan head screw ST3.9x16 (4 pcs).
xx1200000045
Attachment screws:
M6x16 quality 8.8-A2F (3 pcs)
Continues on next page
Continued
89