2 Installation
2.2.7 Fitting the attachments of IRBDP SW6 & MH6 UI/LE (Lean ID)
Continued
Fitting the housing, lower part
Use this procedure to fit the housing, lower part.
1
2
Continues on next page
90
Action
Fit the housing, lower part, to the lower
bracket.
Lock screws with locking liquid (Loctite
243).
Fit the housing, lower part, one on each of
the brackets for cable clamp.
Lock screws with locking liquid (Loctite
243).
© Copyright 2007-2018 ABB. All rights reserved.
Note
xx1200000022
Attachment screws:
M8x16 quality 8.8-A2F (2 pcs)
xx1200000023
Attachment screws:
M8x16 quality 8.8-A2F (2+2 pcs)