The figure shows the Air supply circuit with an Electrical Proportional valve.
xx0600003460
A
B
Location of Air supply circuit, type Sb
The Air supply circuit is located as shown in the figure below.
There are two versions available of the Air supply circuit - with an Electrical
Proportional Valve (EP) or without one.
xx0800000124
A
B
C
D
E
F
G
Product manual - DressPack/SpotPack IRB 6640
3HAC028638-001 Revision: K
Air supply circuit
Electrical Proportional Valve (EP)
Air supply circuit
PROC 1 on robot base
PROC 2 on robot base
PROC 3 on robot base
Shop water supply
Shop water drain
PROC 4 on robot base (option)
© Copyright 2007-2018 ABB. All rights reserved.
4.4.1 Replacement of Air supply circuit
Continues on next page
4 Repair
Continued
313