Quidway S8500 Series Routing Switches

2.3.19 timer realtime-accounting

Syntax
timer realtime-accounting minutes
undo timer realtime-accounting
View
HWTACACS view
Parameter
minutes: Real-time accounting interval, which is in the range of 3 to 60 minutes and
must be a multiple of 3. By defaults, it is 12 minutes.
Description
Use the timer realtime-accounting command to set the real-time accounting interval.
Use the undo timer realtime-accounting command to restore the default interval.
The setting of real-time accounting interval is necessary for real-time accounting. After
an interval is set, the NAS transmits the accounting information of online users to the
TACACS accounting server periodically.
The setting of real-time accounting interval somewhat depends on the performance of
the NAS and the TACACS server: a shorter interval requires higher device performance.
You are therefore recommended to adopt a longer interval when there are a large
number of users (more than 1000, inclusive). The following table lists the numbers of
users and the recommended intervals.
Table 2-4 Number of users and recommended interval
Number of users
1 – 99
100 – 499
500 – 999
ú1000
Example
# Set the real-time accounting interval of the HWTACACS scheme huawei to 51
minutes.
[Quidway-hwtacacs-huawei] timer realtime-accounting 51
Chapter 2 AAA and RADIUS/HWTACACS Protocol
Real-time accounting interval ( in minutes)
3
6
12
ú15