Display Clock Device - Huawei Quidway S8500 Series Command Manual

Routing switches
Hide thumbs Also See for Quidway S8500 Series:
Table of Contents

Advertisement

Command Manual – System Management
Quidway S8500 Series Routing Switches
Description
Use the clock stop warm-up command to force the clock module to stop warming up
the local oscillator and switch into normal work.
Example
# Force the clock module to stop warming up the local oscillator and switch into normal
work.
<Quidway> system-view
System View: return to User View with Ctrl+Z.
[Quidway] clock stop warm-up

4.2.9 display clock device

Syntax
display clock device
View
Any view
Parameter
None
Description
Use the display clock device command to query the detailed information of the clock
device.
Example
# Query the detailed information of the clock device.
<Quidway> display clock device
Clock module detail information:
Clock module state is OK
SRAM state: OK
Output 38.88Mhz signal state: OK
PLL tru050 state: OK
PLL 88915 state: OK
OSC state: OK
I2C bus state: OK
EPLD state: OK
HDLC state: OK
E1 A state: OK