Huawei Quidway S8500 Series Command Manual page 1128

Routing switches
Hide thumbs Also See for Quidway S8500 Series:
Table of Contents

Advertisement

Command Manual – System Management
Quidway S8500 Series Routing Switches
Syntax
rmon alarm entry-number alarm-variable sampling-time { delta | absolute }
rising-threshold threshold-value1 event-entry1 falling-threshold threshold-value2
event-entry2 [ owner text ]
undo rmon alarm entry-number
View
System view
Parameter
entry-number: Number of the entry to be added/deleted, ranging from 1 to 65535.
alarm-variable: Specifies the alarm variable with a character string, ranging from 1 to
256, in the OID dotted format, like 1.3.6.1.2.1.2.1.10.1 (or ifInOctets.1).
sampling-time: Specifies the sampling interval, ranging from 5 to 65535 (measured in
seconds).
delta: Sampling type is delta.
absolute: Sampling type is absolute.
rising-threshold threshold-value1: Rising threshold, ranging from 0 to 2147483647.
event-entry1: Event number corresponding to the upper limit of threshold, ranging from
0 to 65535.
falling-threshold threshold-value2: Falling threshold, ranging from 0 to 2147483647.
event-entry2: Event number corresponding to the falling threshold, ranging from 0 to
65535.
owner text: Specifies the creator of the alarm. Length of the character string ranges
from 1 to 127.
Description
Use the rmon alarm command to add an entry to the alarm table.
Use the undo rmon alarm command to cancel an entry from this table.
In this way, the alarm event can be triggered in the abnormal situations and then
decides to log and send trap to the NM station.
Note:
Before adding an alarm entry, you need first to define the event to be referenced in the
alarm entry using the rmon event command.
Huawei Technologies Proprietary