Command Manual – System Management
Quidway S8500 Series Routing Switches
Use the display rmon prialarm command to view information about extended RMON
alarm table.
Related command: rmon prialarm.
Example
# Display the information about extended RMON alarm table.
<Quidway> display rmon prialarm
Prialarm table 1 owned by monitor is UNDERCREATION.
Samples type
Variable
(.1.3.6.1.2.1.2.2.1.10.201326601+.1.3.6.1.2.1.2.2.1.16
.201326601)*8*100/.1.3.6.1.2.1.2.2.1.5.201326601
Description
Sampling interval
Rising threshold
Falling threshold
When startup enables
This entry will exist : forever.
Latest value
Table 6-5 Description on the fields of the display rmon prialarm command
Prialarm table 1
owned by monitor
UNDERCREATION
Samples type
Variable formula
Description
Sampling interval
10(sec)
Rising threshold
Falling threshold
linked with event 1
When startup enables:
risingOrFallingAlarm
: changeratio
formula
: ifUtilization.Ethernet5/1/1
: 10(sec)
: 50(linked with event 1)
: 5(linked with event 1)
: risingOrFallingAlarm
: 0
Field
Index of extended alarm entry.
Creator of the extended alarm entry.
Status of expansion alarms
Type of sampling
Formula for expansion alarms
Description information
:
Sampling interval
Rising threshold. When sampling value rises from
normal value to this threshold, rising threshold alarm will
be triggered.
Falling threshold. When sampling value decreases from
normal value to this threshold, falling threshold alarm will
be triggered.
Corresponding event index of ring and falling threshold
alarm.
Kind of first alarm. It may trigger rising threshold alarm or
falling threshold alarm or both.
Huawei Technologies Proprietary