Table 3-2 Description on display information
Board 0 CPU busy status:
6% in last 5 seconds
7% in last 1 minute
12% in last 5 minutes

3.1.5 display device

Syntax
display device [ detail | [ shelf shelf-no ] [ frame frame-no ] [ slot slot-no ] ]
View
Any view
Parameter
detail: displays all slot detail information.
shelf-no: Shelf number.
frame-no: Frame number.
slot-no: Slot number.
Description
Use the display device command to display the module type and working status
information of a card, including physical card number, physical daughter card number,
number of ports, hardware version number, FPGA version number, version number of
BOOTROM software, application version number, address learning mode, interface
card type and interface card type description, and so on.
Example
# Show device information.
<Quidway> display device
Slot No.
0
1
2
3
4
5
6
Field
Brd Type
Brd Status
LSB1SRPB
Master
NONE
Absent
NONE
Absent
NONE
Absent
NONE
Absent
NONE
Absent
NONE
Absent
Huawei Technologies Proprietary
Chapter 3 Device Management Commands
CPU usage of switch
CPU usage in last 5 seconds is 6%.
CPU usage in last 1 minute is 7%.