Command Manual – PoE
Quidway S8500 Series Routing Switches
Hardware Version
CPLD Version
Table 1-2 Description on the fields of the display poe pse command
Power Current Value
Power Remaining Value
Power Max Value
Power Peak Value
Power Average Value
Software Version
Hardware Version
Note:
The sampling cycle of the current power of the interface card is 1 minute, and the
sampling cycle of the peak power and average power is 5 minutes.

1.1.4 display poe slot

Syntax
display poe slot slotnum
View
Any view
Parameter
slotnum: Slot number of a PoE card
Description
Use the display poe slot slotnum command to display the information of a PoE card in
the switch.
Example
# Display the information of the PoE card in slot 8 of the switch.
[8508] display poe slot 8
PSE Information of board 8:
Power Current Value
:000
:021
Field
:33 W
Huawei Technologies Proprietary
1-4
Chapter 1 PoE Configuration Commands
Description
Current power of the card
Remaining power of the card
Maximum power of the card
Peak power of the card
Average power of the card